Skip to content

ECAM COND page

Back to ECAM System Display Overview

ECAM COND page

Number Name Variation Meaning
1 Zone controller fault indication Hidden The zone controller is within normal operations
Green ALTN MODE The primary zone controller is faulty.
Green PACK REG The zone controller is faulty.
2 Cabin Fan fault indication Amber FAN The recirculation fan is faulty.
Hidden The recirculation fan is within normal operations.
3 Zone temperature indication Green number The temperature of the zone .
4 Zone duct temperature Green number The temperature of the zone duct.
Amber number The temperature is greater than 80 °C.
5 Zone trim air valve position Green C The cold valve is fully closed
Green H The hot valve is fully open
Amber XX The valves have failed.
6 Hot air pressure regulating valve Green crossline The pushbutton is at AUTO and the valve is fully closed.
Amber crossline The pushbutton is OFF and the valve is closed, or the valve is not coordinated with the control position.
Green inline The valve is open.
Amber inline The valve is open, but it is not coordinated with the control position.
7 Temperature unit Green number The unit of temperature indications.

Last update: September 17, 2023